Cardiac Magnetic Resonance Imaging versus Transthoracic Echocardiography for Detecting Left Ventricular Thrombus in Patients with Reduced Ejection Fraction: A Retrospective Observational Study

dc.contributor.authorNasir, Zainab
dc.contributor.authorFarooq, Umar
dc.contributor.authorDurrani, Misbah
dc.contributor.authorSaleem, Shafaq
dc.contributor.authorHaq, Abair Ul
dc.contributor.authorYousaf, Muhammad Husnain
dc.date.accessioned2026-09-05T09:18:39Z
dc.date.copyright2021
dc.date.issued2026-07-22
dc.description.abstractObjectives: To compare the diagnostic performance of transthoracic echocardiography and cardiac magnetic resonance imaging for the detection of left ventricular thrombus in patients with reduced ejection fraction. Methodology: This retrospective observational study included 59 patients with LVEF ≤40% who underwent both TTE and CMR between January 2022 and December 2023 at a tertiary cardiac center. CMR was used as the reference standard for LVT detection. Diagnostic accuracy parameters, including sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), were calculated for TTE. Results: Transthoracic echocardiography detected left ventricular thrombus in 3.4% of patients, whereas CMR identified thrombus in 76.3%. TTE demonstrated very low sensitivity (4.4%) but high specificity (100%). In contrast, CMR achieved 100% sensitivity, specificity, PPV, and NPV. The study population had a high prevalence of diabetes, obesity, and hypertension. Conclusion: Cardiac magnetic resonance imaging significantly outperforms transthoracic echocardiography in detecting left ventricular thrombus in patients with reduced ejection fraction. While TTE remains a valuable screening tool due to its accessibility, its low sensitivity limits its reliability for excluding LVT. In high-risk patients, CMR should be considered to ensure accurate diagnosis and optimal clinical management.
dc.format.extentpp. 931-937
dc.identifier.citationPakistan Heart Journal; Vol. 59 No. 4 (2026), pp. 931-937
dc.identifier.doi10.47144/phj.v59i4.3257
dc.identifier.urihttps://pakheartjournal.com/index.php/pk/article/view/3257
dc.identifier.urihttps://ds.pakheartjournal.com/handle/phj/1072
dc.language.isoen
dc.publisherPakistan Heart Journal
dc.relation.ispartofseriesPakistan Heart Journal; Vol. 59 No. 4 (2026)
dc.rights.holderPakistan Heart Journal
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0
dc.titleCardiac Magnetic Resonance Imaging versus Transthoracic Echocardiography for Detecting Left Ventricular Thrombus in Patients with Reduced Ejection Fraction: A Retrospective Observational Study
dc.typeArticle
person.identifier.orcidhttps://orcid.org/0009-0006-2942-8811
person.identifier.orcidhttps://orcid.org/0009-0006-5071-4070
person.identifier.orcidhttps://orcid.org/0000-0001-9628-5255
person.identifier.orcidhttps://orcid.org/0009-0002-9878-8379
person.identifier.orcidhttps://orcid.org/0009-0003-9655-1623

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
6a902a8a687a2.pdf
Size:
616.22 KB
Format:
Adobe Portable Document Format

Collections